GVS SERIES: THE MANIFOLD WATER HEATERS

The efficiency of Gas Heating and the convenience of a large water heater.
These, together with the real fact the
IDROPI wall gas fired water heater is simple, silent, cheap and safe.
The GVS tank is protected against the corrosion by glass lined process executed in compliance with norms DIN 4753.
The gas valve, set at the bottom, makes the gas fired water heater more up-to-dated and upright in its appearance.
The valve-gas burner group makes assembling and disassembling easier, avoiding the risk of a gas leak due to the pipe-fitting slackening.
This conformation makes ordinary maintenance such as combustion chamber cleaning, exhaust check up, nozzle changing and so on, easier.
Thanks to a capacity range from 50 up to 120 litres, all domestic needs are satisfied in line with the highest lifestyle standards.
The GVS are equipped with a thermostatic valve containing a device which interrupts the gas flux immediately in case of combustion lack; moreover, the valve is equipped with a safety thermostat which kicks in case of over-heating. An additional safety devise is the fume thermostat, which interrupts the gas flow if smokes emissions are hampered.
This is equipped with a magnesium anode in order to avoid the corrosion process.
A thick and dense polyurethane foam insulation, at the same time, minimises the thermic leaks and helps in energy savings.
CHIMNEY

Chimney, to be arranged by the client, must have a straight height of minimum 3' above hood & of the matching dia of the hood. All 90 degree bends are to be smooth & long curved & not short bend.
Try to minimise the bends. The chimney is explained as below in the sketch.
| TECHNICAL DATA |
STORAGE SERIES |
| FEATURES |
NATURAL DRAUGHT |
| SERIES |
GVS |
| MODEL |
50 |
80 |
T 80 |
100 |
T 100 |
120 |
| Mounting System |
UNIT |
WALL HANGING |
| Rated Power with G20-Natural Gas |
kW |
4.2 |
5.8 |
5.8 |
5.8 |
5.8 |
5.8 |
| Useful Power with G20-Natural Gas |
kW |
3.5 |
4.8 |
4.8 |
4.8 |
4.8 |
4.8 |
| Rated Power with G300-G31-LPG |
kW |
4.0 |
5.2 |
5.2 |
5.2 |
5.2 |
5.2 |
| Useful Power with G300-G31-LPG |
kW |
3.3 |
4.4 |
4.4 |
4.4 |
4.4 |
4.4 |
| Efficiency |
% |
84 |
84 |
84 |
84 |
84 |
84 |
| Utilizable Gas |
G20-Natural Gas |
|
yes |
| G30-LPG |
|
yes |
| G31-LPG |
|
yes |
| Consumption |
G20-Natural Gas |
m3/h |
0.45 |
0.61 |
0.61 |
0.61 |
0.61 |
0.61 |
| G30-LPG |
kg/h |
0.32 |
0.41 |
0.41 |
0.41 |
0.41 |
0.41 |
| G31-LPG |
kg/h |
0.30 |
0.40 |
0.40 |
0.40 |
0.40 |
0.40 |
| Burner |
|
inox multigas |
| Heating Time Δt° 40 °C |
min |
36 |
46 |
46 |
55 |
55 |
67 |
| Continous Production at 40 °C* |
lt/h |
118 |
162 |
162 |
162 |
162 |
162 |
| Temperature Adjustment |
|
yes |
| Gas Safety Valve |
|
yes |
| Over-Heating Safety Cut-Off |
|
yes |
| Hydraulic Safety Valve |
|
yes |
| Smoke Exaust Safety Thermostat (Cut-Off) |
|
yes |
| Thermometer |
|
yes |
| Piezo Ignition |
|
manual |
| Maximum Working Pressure |
bar |
8 |
| Tank Material |
|
steel |
| Protection of the Tank against Corrosion |
|
glass lined according to norm DIN 4753+replaceable
magnesium anode |
| Replaceable Magnesium Anode |
|
yes |
| Thermal Insulation |
|
injected polyurethane foam CFC free |
| Connections |
Hot water outlet |
inch |
Ø 3/4" M |
| Cold water inlet |
inch |
Ø 1/2" M |
| Recycle |
inch |
no |
| Gas |
inch |
Ø 3/8"F |
| Smoke Exaust Pipe Diameter |
mm |
80 |
80 |
80 |
80 |
80 |
80 |
| Heat Exchanger |
m2 |
|
|
0.6 |
|
|
0.6 |
| Maximum length Coaxial Pipe |
m |
- |
| Tension/Frequency/Power |
V/Hz/W |
- |
| Package |
Height |
cm |
55 |
77 |
77 |
89 |
89 |
101 |
| Width |
cm |
50 |
50 |
50 |
50 |
50 |
50 |
| Depth |
cm |
50 |
50 |
50 |
50 |
50 |
50 |
| Weight |
Net |
Kg |
22 |
29.5 |
38.5 |
34 |
43 |
38 |
| Gross |
Kg |
24 |
32 |
41 |
36.5 |
45.5 |
41 |
| Certificates |
|
 |
| * Cold water temperature reference 15 °C |